• 8" Low Pressure Solenoid Operated Diaphragm Pulse Valve for Power Plant
  • 8" Low Pressure Solenoid Operated Diaphragm Pulse Valve for Power Plant
  • 8" Low Pressure Solenoid Operated Diaphragm Pulse Valve for Power Plant
  • 8" Low Pressure Solenoid Operated Diaphragm Pulse Valve for Power Plant
  • 8" Low Pressure Solenoid Operated Diaphragm Pulse Valve for Power Plant
  • 8" Low Pressure Solenoid Operated Diaphragm Pulse Valve for Power Plant

8" Low Pressure Solenoid Operated Diaphragm Pulse Valve for Power Plant

Media: Gas
Temperature: Ordinary Temperature
Actuator: Electric
Connection Form: Thread
Type: Pilot Operated
Material: Aluminum
Customization:
Gold Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
DMY-II-200C
Pressure
Low Pressure
Valve Structure
Pilot Membrane Structure
Power Supply
DC Solenoid Valve
Usage
Dust Cleaning
Standard
ANSI
Application
Industrial Usage
Package
Export Standard
Transport Package
Carton Box`
Specification
8"(DN200)
Trademark
XIE CHANG
Origin
China

Product Description

1. Pulse valve used for rotating cleaning low pressure baghouse 
2. Garlock membrane used 
3. ISO9001:2008/CE certified 
4. World-class diaphragms


Pulse Valve Introduction
       With the standard of dust emission from the power industry being further enhanced, high-efficiency baghouse filter has been widely promoted and used in power plant industry.
       Presently, the long-arm rotating baghouse is polularly used in power industry, the feature of which is suitable for the dust wind with high air volume, small wokload of maintenance, high blow volume, low pressure and energy saving, etc. The heart part system of pulse valve is usually imported from abroad the 8" Pulse Valve while the most of Pulse Valve produced domestically is at most 3" which can not meet the requirement of high blow jetting volume. To satisfy the high speed development of APC requirement, we have developed 8", 10", 12", 14" and 16" low pressure pulse valve. After the experimental test, all the performance have reached the foreign standard. Welcome the users to select.
Working Principle
The low pressure large-orifice pulse valve stop working by the differential pressure between the both sides of diaphragm. The pilot head of Pulse Valve open the balancing holes with time of pulse duration ( 0.15-0.3s). The airflow in the high pressure area of diaphragm will be released so that the diaphragm will be holded up and the Pulse Valve start cleaning.
 
Technical Parameters
>Pulse Valve Working pressure:0.05~0.1Mpa
>Pulse Valve Working medium:clean air
>Pulse Valve Voltage:DC24V(AC220V/50Hz)
>Pulse Valve Current:0.8A(0.05A)
>Used environment:
Temperature:-40°C~130°C
The relative humidity of air is no more than 85%
8" Low Pressure Solenoid Operated Diaphragm Pulse Valve for Power Plant
8" Low Pressure Solenoid Operated Diaphragm Pulse Valve for Power Plant


 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Registered Capital
5.55 Million USD
Plant Area
33625.01 square meters